SpectroRadiometers-
General Lighting

Spectroradiometers
Instruments for Light Measurement |
|
SpectroRadiometer PDF Download
|
|
The StellarNet model spectrometers
are great tools for low cost, routine analysis of all types of
light. From measuring the irradiance of standard light bulbs
to measuring the exact color coordinates of the yellow in a traffic
light, StellarNet spectrometers are used worldwide to routinely
analyze light. These instruments are calibrated to measure
the spectral irradiance in units of watts per meter squared over the
wavelength range in nanometers provided by the selected spectrometer
model. Currently, StellarNet offers Radiometer systems in the
200-1700nm range. The the bottom of the page details the various ranges for each StellarNet Spectroradiometer.
The BLUE and
GREEN-Wave models, BLACK-Comet concave grating model, and
RED-Wave-NIR
InGaAs model can be configured to have the correct slit size and
detector array to suite your application. Calibrated
spectroradiometers can be used to measure absolute intensity,
xy chromaticity (CIE 1931), purity, correlated
color temperature, and dominant wavelength.
New StellarNet
Low Cost Integrating Spheres
 |
|

Why StellarNet
SpectroRadiometers?
- UV-VIS-NIR Ranges 200-1700nm
- Low cost -
Ruggedized - high
performance
- Shock-proof - Permanently aligned
- SpectraWiz Software included Free
- Battery packs for field measurements
- USB-2 interface to all notebook PCs
- Measurement accessories for many applications
|
|
For application specific
StellarNet Spectroradiometer configurations and example spectra
visit the links below.
StellarNet
SpectroRadiometers for LED Measurement
StellarNet
SpectroRadiometers for Laser Measurement
StellarNet
SpectroRadiometers for Solar Measurement
SpectraWiz Software included FREE
-
Absolute intensity
measurements watts/m2
-
µm
watts/cm2
- PSD
- Lumens/m2
-- LUX
- Moles
per second -- PAR
- Footcandles /m2
- Radiant Flux (watts) /
Luminous Flux (lumens)
- xy Chromaticity, dominant
wavelength, purity
- Correlated
color temperature (CCT)
- Set Power Spectral
Density (PSD) range
Standard and Extended Ranges
StellarNet also has extended range
spectroradiometers
available to measure spectral irradiance over a wide range of
wavelengths. The EPP2000-UVN-SR spectroradiometer with CCD detector array covers a range of 200-1100nm.
The
BLACK-Comet-SR super range, dual blazed, concave grating spectroradiometer
offers a range of 220-1100nm while retaining
all of the characteristics of a concave grating spectrometer!!! In
addition, StellarNet offers a Dual Channel Spectrometer system for
spectroradiometry, the Dual DSR (Detector Super Range) combines a CCD
and InGaAs detector to cover a wavelength range of 200-1700nm for
selected models.

|
|
NIST Calibrations
See more StellarNet Measurement Diagrams!!

Experimental Setup for Laser, Laser
Diode, and LED characterization. Larger Spheres
such as IS6 and IS12 can be used in place of low cost IC2.

StellarNet Cosine Receptors allow collection of
light with an 180 field of view using demountable diffusers
with ~10% loss. The
CR1-UVN
is a ½” diameter
near
cosine receptor using a
sanded fused
silica diffuser for 200-1700nm and has reduced 90° FOV and
only low 7% loss.
Cosine Receptor PDF
  
StellarNet Integration
Spheres allow collection of
light with an 180 field of view. The IC2 is
a 2" internal diameter sphere with 2 SMA connectors for illumination
and collection of LED light. The input port is 5/8". The IS6
and IS12 are 6" and 12" StellarNet integration spheres with 2.5"
input port with internal white coating. Mounting tripods
and other accessories are available for LED measurement.
Integration Sphere PDF
Integration Sphere
Pricelist

SpectraWiz
Software displaying 1931 xy chromaticity diagram measuring
the color and Correlated Color Temperature
(CCT) of an LED.

SpectraWiz Software
allows the users to select the
irradiance units. Additionally, scroll down menus allow the user to
select their collection accessory in order to calculate radiant and
luminous flux.

BLACK-Comet
spectrometer calculating LUX values of a bright source. StellarNet
spectroradiometers are all calibrated first with base units of
irradiance in W/m^2. SpectraWiz software applies different factors
and algorithms in real-time to calculate your favorite comparison
value (e.g. Lumen, footcandle, CCT, etc). |
| |
|

Dual DSR Spectroradiometer-
Halogen-lamp spectra (300-1700nm).
StellarNet Dual DSR system pictured above uses a Y
bifurcated fiber (F600-Y-UVSRNIR)
to connect a BLACK-Comet-SR spectrometer and a RED-Wave NIR
Spectrometer. The entire system can be radiometrically calibrated
over the range 200-1700nm. Above system pictured with Flash Capture
Interface (FCI) that allows spectrometer to capture emission from
flashing sources such as flashtubes and pulsed solar simulators. |
|
Low Light Configurations-
Many popular applications involve measuring the
irradiance of light sources with low output intensities. From
ambient streetlight to UV-LEDs many people need to detect low levels
of radiation. StellarNet spectrometers can be specially configured
to measure these low light levels. The spectrometer aperture
or slit can be adjusted to allow more light into the unit, thus
making it more sensitive to radiation. For low light
applications a 200um slit is the standard slit size.
Additionally, low light level calibrations can be employed to
further optimize the spectrometers ability to see low light levels.
And lastly, a TEC cooler can be installed on the detector array to
increase the signal to noise of the unit by 66%. This in
affect allows the spectrometer to integrate over longer periods of
time, collecting more and more photons, while keeping a low noise
value. If you have a low light application be sure to talk to a
StellarNet sales engineer to discuss the configuration of your
spectrometer.
Bright Light Configurations-
In contrast, many industries require the measurement of
really bright light emission. StellarNet spectrometers have a
dynamic range of 6 decades allowing integration times from 1ms to
65s. StellarNet spectrometers can be specially configured for high
power applications. The limitation of a high power radiometer will
be limited by the power of the calibration source. StellarNet can
configure Spectroradiometers to optimize calibration thus allowing
the use of the units large dynamic range and detector linearity to
allow high power light measurement. Additionally, smaller slits,
fibers, and integration spheres can be employed to decrease the
signal to the spectrometer. StellarNet offers a high
light level calibration to further optimize the system performance. |
|

EPP2000-UVN-SR
Metal Halide and High Power Sodium Lamps displaying Area Power
Spectral Density, Centriod, Peakwave, FWHM, and CentBase.
Power and InterFace
Portable spectrometers include
a high speed USB-2 interface cable.
All miniature spectrometers with a CCD detector (GREEN-Wave, BLUE-Wave,
BLACK-Comet, and new EPP2000 models) are powered by your computer's USB port while
spectrometers with InGaAs detectors (RED-Wave) require an external 5V
supply. New Big Wave electronics allow plug in play operation
through on board memory where all coefficients are automatically loaded
into your software.
 |
|
|
|
|

|
Item |
Miniature Fiber Optic
SpectroRadiometers |
Price |
|
BLACK-Comet |
Concave
Grating spectrometer for UV-VIS.
C
(190-850nm) or
CXR
(280-900nm) |
$2,750 |
|
BLACK-Comet
"SR" |
Super
Range
Concave
Grating spectrometer for UV-VIS-NIR.
C-SR
(200-1080nm) or CXR-SR
(220-1100nm) |
$3,495 |
|
EPP2000-UVN-SR |
EPP2000 series spectrometer for UV-VIS-NIR (200-1100nm) with
plane grating |
$3,495 |
|
RED-Wave-NIR-512 |
NIR Spectrometer,
range 900-1700nm, with cooled
512
element PDA detector |
$13,125 |
|
RED-Wave-NIR-1024 |
NIR Spectrometer,
range 1000-1700nm, with cooled
1024
element PDA detector |
$17,695 |
|
DSR-CSR-512 |
BLACK-Comet model
C-SR
(UV-VIS-NIR, CCD) and
RED-Wave-NIR-512
(InGaAs PDA) for 200-1700nm |
$16,620 |
|
DSR-CSR-1024 |
BLACK-Comet model
C-SR
(UV-VIS-NIR, CCD) and
RED-Wave-NIR-1024
(InGaAs PDA) for 200-1700nm |
$21190 |
|
|
NIST Traceable
Calibrations per spectrometer channel |
|
|
IRRAD-CAL |
SpectroRadiometric
Calibration VIS-NIR for range 300-1100nm
or 900-1700nm |
$250 |
|
IRRADUVN-CAL |
SpectroRadiometric Calibration VIS-NIR for range
300-1700nm
|
$500 |
|
IRRADUV-CAL |
SpectroRadiometric Calibration UV for range 200-400nm
|
$250 |
|
RAD-CAL |
Radiant power calibration (flux) in Watts/nm and Lumen/nm
(for LEDs) 300-1100nm |
$250 |
|
RAD-CAL-SR |
Radiance calibration in Watts/sr/m^2/nm can measure Cd/m^2/nm
- requires CR-LENS for CR2 |
$250 |
|
IRRAD-CAL-DOC |
Optional
Irradiance Calibration
certificate with NIST traceable serial numbers |
$125 |
|
|
Fiber Optic
Accessories for Irradiance Measurements |
|
|
CR2 |
CR2
Cosine Receptor for UV-VIS-NIR
1/4 inch diameter
and 180° field of view |
$125 |
|
CR2-AP |
Screw on 10% aperture for CR2,
allows measurement of light that is 10 times brighter |
$125 |
|
IC2 |
Integrating Cube Receptor (Sphere), 2 x2 x2 inches with 5/8
inch input port |
$495 |
|
IS6 |
6” integrating sphere with a 2.0” input
port, 1 SMA fiber optic output, and internal white coating |
$1745 |
|
IS12 |
12” integrating sphere that allows
for internal mounting of devices
for light measurement such as discrete
LEDs, arrays, and bulbs. The sphere opens for simple
access to mounting devices. IS12 Sphere includes lamp
with data file used to calibrate the system for total
flux measurements in watts/nm and
lumens/nm. |
$3495 |
|
F600-VISNIR |
Armored 2 meter fiber optic cable attaches Receptor to
SpectroRadiometer |
$140 |
|
F600-UVVIS-SR |
Armored Solarization Resistant 600um fiber
optic cable - 2 meters |
$195 |
|
IC2-TP |
Tripod for mounting and positioning IC2 light receptors |
$49 |
*Note: actual spectrometer range can be smaller
than range described for radiometric calibration
*Please contact a StellarNet sales representative about more
spectrometer configurations
|
|
|
|
|